The company prides itself on manufacturing Boiler leaks usually happen due to blown pump seals. And on Page 14 under Setting The Boiler Temperature it says 'Turn the heating . The perfect home heating solution for small to medium sized properties, the Worcester Bosch Greenstar 30i ErP combi boiler is just as powerful as it is efficient. The price of an installed Worcester Bosch Boiler can vary wildly between installers, sometimes upwards of 30%. Controls The control panel on the front of the boiler offers all the same features of a standard combi boiler, with an on/off switch, temperature settings, and an LED to display fault diagnostics. Cause: Normally, an overheating boiler will be caused by faulty fans or pumps. . From this 55 degree flow temperature set-point, if you are not getting the home warm, you can increase by 1-2 degrees at a time, let the system run for a day and then repeat as necessary. Compact and ideal for smaller properties. Simple boiler control knobs with clear temperature display; Low energy pump reduces electrical usage;. Don't think. Although Worcester Bosch combi boilers are some of the most expensive in the industry, they do provide some of the best combi boilers in terms or performance available. When the boiler comes on in the morning, the radiators het hot and the temperature quickly reaches 20 degrees (one degree lower than that set on thermostat). The only difference between having an 80 degree flow temperature to a 60 degree flow temperature is that a property will take longer to reach the set temperature at the lower flow temperature. They also don't store water, heating water straight from the supply on demand instead. Recheck the boiler to make sure it is working. As a rule, setting your heating control to 75 degrees should be sufficient to give you a perfectly warm house, while also allowing your boiler to run as economically as possible. 1. And it's definitely running colder . Frost protection and heating of domestic hot water will stay active'. Worcester Bosch Combination Flow Rates Explained Will a Worcester Bosch combination Boiler (or any other Brand of Boiler) increase or improve your water pressure or flow rate (sometimes referred to as flow volume) ?? Low boiler pressure. That extra 5kW of power increases the flow rate up to 12.3l/min. 5 Year Warranty. If you have children, being able to control the hot water temperature is essential, as you can prevent scalding hot water from reaching the taps. Best Settings for a Worcester Bosch Wave System Worcester Bosch system boiler prices. I think I read somewhere that optimum temp is 80 for efficiency so probably do need to get the boiler looked at. This happens due to the condensate pipe running outside and is an issue that you could fix yourself, if you feel confident enough. The central heating is fine but when we run a bath, we used to have to add cold water to it - now we can fill the dc' s bath without any cold at all. Flow Temp - Worcester bosch greenstar i reduce flow temperature 82 to 55 degrees - MyBoiler.com WINTER ALERT Due to the unexpected energy crisis, home energy bills will be sky rocketing this winter, see our Money and Energy Saving page to see if there is anything further that you can do. The more powerful Highflow combi boiler has 19 fault codes and is detailed below with the relevant description and fix. Some boilers have 'e' on the dial which stands for economy. set your boiler temperature to 65C in summer (between medium and low) and adjust down if your water feels too hot. But it's important not to set it any lower than that. At night, when you're nice and covered up, then you can consider lowering the temperature to 14 or 15C. Looking in the user manual of my Worcester CDi29 combi boiler there is a section 'Holiday Mode' which I was going to use while away for a few weeks during the winter. If you have a blue light flashing on your Worcester boiler, a simple trick is to press and hold the reset button on the boiler control panel's back to reset it. In this blog we cover turning off Worcester pre-heats. Standard Delivery (3 - 7 days) FREE. You shouldn't need to adjust these output temperatures as you may alter the boiler's efficiency. The ideal temperature when having a bath or washing the dishes is down to personal preference. For setting Max Worcester say 88 (that seems a big jump to me) and boiler is getting to 74. Worcester boiler water pressure issues are common, especially for those that have been in use for some time. It can also provide a boost in cold weather if your hot water is not quite hot enough. This a short video on how to set the hot water and central heating temperatures on a new Worcester-Bosch boiler we installed in West Dumbartonshire www.lcdh. . Switching the boiler on/off 7 Setting the temperature 7 Controlling central heating 7 Frost protection 7 Controlling the hot water temperature 8 . . Worcester Bosch offer a wide variety of boiler controls, which range from standard room thermostats, through to smart thermostats. Worcester 240 Combi RSF . For setting 6 Worcester say 75 and Dh said 81. The 'ECO' button explained ECO illuminated green = energy saving economy mode, preheat off, slight increase in the length of time for hot water to be delivered. Worcester Boiler Overheating. No need for a hot water cylinder. During the day, you could set your Worcester Combi Boiler at a temperature of 6 to 8C if you're not home. A Worcester 30i boiler is powerful enough to handle the central heating and hot water needs of a medium sized home with around 15 radiators and up to two bathrooms. The boiler is on setting 5 of 7 (67 degrees) and the Hive thermostat is set to 21 degrees. And on Page 14 under Setting The Boiler Temperature it says 'Turn the heating temperature control to the desired level between 40c and 90c'. When the system is cool, the pressure gauge on a Worcester boiler should be between 1 - 1.5 (in the green section). Money and Energy Saving x The best temperature for your hot water cylinder is between 140-150 degrees Fahrenheit. Once the set temperature is reached, then the boiler will shutdown. It has a high central heating output of 30kW, making it powerful enough to heat between 15 and 20 radiators, in a large, spacious 4-bedroom home. When water pressure is low on a Worcester boiler it can . OFTEC is a trade association that takes a lead role in setting industry standards of oil-fired boilers. Capable of delivering flow rates up to 12.3 litres per minute and with a 30kW output, . If your Worcester Bosch boiler is leaking, this can lead to low boiler pressure, which will in turn cause the combi boiler to lock out and thus halt your heating system. You may find that 55 degrees set-point works for most of the year except very cold days. Buying Options. 1,357.18 inc VAT. . If you're looking for a good balance of warmth and efficiency, you want to set your boiler to at least 65C. Worcester combi boilers, taking water directly from the mains to heat up, will always have some hot water in the boiler, whether preheated or not. Set the water temperate to between 60-65 Contrary to the belief that keeping your heating on low all the time is energy efficient, it's actually much better to have your heating on for the periods you're at home and awake. Combi boilers are designed to heat water optimally at certain flow rates stated as litres per minute l/m. Just click on the model or the Gas council number and the manual will download at the bottom of the page. A new combi boiler usually costs between So, if you prefer a cool bedroom at say 16 degrees and a warmer bathroom temperature, simply set the desired temperature levels at the given times. Carol 15-5-2021 2 comments 0 . View photo. Greenstar is the name given to all of the Worcester Gas fired boiler range, and signifies high energy efficiency, reliability and comfort. 87186643010 Worcester Greenstar 37CDi RSF Combi Set Of Electrodes. The answer is NO What the water pressure? Most Worcester boilers come with the pre-heat turned on, so you will need to turn it off. Sorry about the delay in replying. Worcester Bosch Greenstar 34CDi Classic Combi. Combi boiler for combi boiler replacement, . Big difference here. Provides instantaneous hot water for properties with up to 3 bedrooms and 2 bathrooms with a high output demand. The boiler is a Greenstar 30CDi. The best setting for combi boilers is often recommended as 75C for central heating and 60C for domestic hot water. Well for a radiator, the recommended output temperature is 75C. Caleffi Temperature Pressure Relief Valve; Bathroom & Kitchen; . A bacteria called Legionella can grow in freshwater with a temperature of 77-112 degrees Fahrenheit. So when a tap is turned on, you will get one or two seconds of hot water, then cold water coming through the pipes before the boiler plays catch up and delivers heated water. Worcester Bosch GB162 Boiler Error Codes RRP 1,395.60 You Save 38.42. How do I lower the temperature on a MT10 boiler. In Stock: Add to cart . . 2) Because the house was cold, more heat was absorbed by the radiators and the water came back at say 45degC on average over the 3 hours - this kept the boiler running the whole time. The Worcester Bosch 30i system boiler can handle even more hot water use, thanks to the fact that it stores hot water in a cylinder and doesn't rely on the pressure of the mains . Firstly, it is sent directly to the radiators when the central heating is ON, so this is the temperature to which the radiators will heat. Manufacturer Model : GC Number Worcester Greenstar 29 HE: 4131156 Worcester Greenstar 25CDI RSF : 4731192. Turning your temperature down to within this range will possibly make your boiler more environmentally-friendly and your bills a little lower. The one I have is only 67% efficient and its bloody freezing in here tonight. A boiler timer, or boiler clock, is a basic control and lets you set the time your system produces hot water. Obviously in the winter months, the water that your boiler is having to heat up is naturally colder to begin with so you may want to adjust the . The flue gases will have about 55dc that will be hotter than the return temp and therefore gives it energy further and reduces the amount of gas usage. Customer support Search for answers in our Troubleshooting section, or call our support team on 0330 123 9339. If you are unsure what is the optimum temperature is for your home, then it should be around 21 degrees which is a comfortable heat. If you work it out manually, 55C will be halfway which will be number 3 on a dial that has numbers from 1 to 6. You most likely control your boiler via a thermostat . The Worcester 42CDi also boasts a hot water output of 42kW and excellent hot water flow rate of 15 l/min. All boilers are fitted with time controlled thermostats, so you can set your heating around your daily routines. For gas boilers, the dew point is around 55 C. Most homes have thermostats and/or TRVs. If the heating and hot water are set to 'off,' your boiler will not come on. Pre it shows around 40 degrees (no heating/water symbol) and when firing up it goes up to around 48/52 degrees (radiator symbol shows) Why is this not the 60 degrees as set for central heating? This water is used by the heating system controls for two different purposes. If you don't have any dials to turn, then you will have buttons. In Stage 2 the house was warmer before you started and you set a higher return temperature say 60deg C Water pressure is the 'force' of the water as it enters your property. They start to reach their very highest efficiency potential at 45C flow temperature or lower, but this can be too low for older properties. This is so bacteria in the water doesn't grow, and cause nasty things like Legionella. This bacteria can put you at risk of contracting a form of . For combi boilers, the recommended output temperature for the radiators is 75 C and for the water is between 50 C and 60 C. Best Settings for your Worcester combi boiler Get a fixed price online in 60 seconds (with installation tomorrow) Get Your Fixed Price Combination boilers are the most popular type of boilers within the UK, providing both a source of heating and hot water within a property, whilst also saving space as there is no need for a water tank. The correct temperature setting for heating on a combi boiler is 'as low as possible', but as a guide most older homes can run their heating systems at 60-65C and newer homes at 50-55C. And for the hot water coming out of your taps, it is personal preference but between 50C and 60C is the recommended temperature. Worcester Greenstar 30Ri Regular Boiler LPG ErP 7733600067. Hold the button down for at most 3-5 seconds to ensure that your boiler is correctly reset. As the cold weather hits the country, many are cranking up the heating temperature.. Boilers often come with an 'eco-mode' function on top of the normal setting. You can find out how in our handy guide. Using Boiler Guide, you can get free quotes for boiler installation from fully-qualified engineers in your local area by taking a few moments to complete our simple online form. In older boilers the timer may look like a clock on the front of the boiler, newer Worcester bosch boilers will show the timer on the front . . If you're seeing the error code EA 229 or D5 on your Worcester Bosch boiler, this means that the condensate pipe is frozen. Repressurise worcester boiler greenstar 30i. However, it could make your hot water too cool for your liking. ShaunCorbs Staff member S. Mod Plumber Gas Engineer Jan 25, 2019 #2 Top 10 Worcester Bosch Boiler Problems. 1) The water left the boiler at say 80 degC. Worcester combis range from 12 to 20 litres depending on the boiler size. Check that the pointer is in the green zone and is around 1.5 bar. The Worcester Bosch Greenstar Highflow CDi Combi Boiler typically costs between 2,053.68 and 2,447.70 including VAT and excluding installation. Different-sized boilers can handle differing flow rates. Maybe the water flow rate is too fast for the Worcester boiler you have installed. For health and safety reasons, try to keep your boiler water temperature from getting too low. Quantity. The simple answer is setting your central heating to a temperature of around 70C and your hot water to 60C should give you the highest efficiency levels for your boiler, although this doesn't. If you're setting your boiler to use the economy mode, you are typically setting it to operate at 65C. Up to 3 boiler installers will get in touch with you, each providing a quotes for you to compare, giving you the greatest chance of finding the most competitive price. Get FREE quotes for a replacement boiler today Arrange an annual service Worcester Boiler Manuals Listed below are all the manuals for Worcester. Turning down the temperature of the domestic hot water is particularly helpful as it can greatly reduce any risk of scalding. [] Renowned for its industry-leading hot water flow rates, the Worcester Bosch Greenstar Highflow CDi Combi is a decent, highly efficient floor standing combination boiler. Or set it to E if there is one there. Most modern boilers will have a digital dial that allows you to set the output temperature. Any advice greatly appreciated!!! The Worcester Bosch 42CDi is a classic combi boiler from the brand's popular Greenstar range. 48.07 inc vat. If it is set to 'timed,' it will only come on between the times you set. On Page 16 under Tips On Energy Saving it says 'The Central Heating Control on the boiler should be set to the maximum rated temperature of the central heating system'. 30 kW Output. #10 - Worcester Boiler Not Responding to Thermostat Commands. Setting the flow temperature on a combi boiler If there are no actual temperature numbers, having it set to around two-thirds of the maximum is normally the best flow temperature to set it at. . And home heating advice service The Heating Hub estimates that you can save another 5-10% if you have a Worcester, Vaillant or Ideal combi boiler by turning off your pre-heat. Pressure relief valve Setting it a few degrees higher won't hurt. Prices start at 1,795 and range all the way up to 2,900, fully fitted. genuine worcester boiler spares direct to your doorstep nextday delivery. Combi boilers let you set a different temperature for heating and hot water. The Worcester 4000 30kw combi boiler is ideal for small to medium-sized homes with up to 16 radiators. Thank you for purchasing a Greenstar gas-fired condensing combination boiler manufactured by Worcester, Bosch Group. The pre-heat function can be switched on and off manually according to your requirements by pressing the 'ECO' button on the front of the boiler. Over the last 6 months, we've noticed our hot water running more and more tepid. A combi boiler will need a flow rate of around 10 litres per minute, although some people argue it should be higher at around 12 litres per minute. Setting this unnecessarily high can be uneconomical and leave you paying more for your bills that you need to. What's the point of setting it on 65/70dc flow temp and return will be about 55/60 you will not use the heat from flue gases at all and that's called wastage or inefficient. However, it states that 'activating it will turn off the central heating system. This enables you to establish different times, and temperatures for your heating and hot water. Having combi boiler temperature settings between 60-65C is generally comfortable for most people. Setting the hot water temperature With combination boilers the water will run cold first for about 10-20 seconds and then turn hot. Running it longer at lower temperatures will save energy compared to higher temperatures when the boiler may have to keep heating and cooling. Hi, DA. Once this is set, you shouldn't need to adjust it. Next, check the pressure gauge. High-powered, compact combi boiler with aluminium silicon heat exchanger. this boiler has set the benchmark within the industry for efficiency and reliability and is suitable for homes with one or tw . CH seems to be fine. Answer this question Add my comment. This means that the water needs to be 55 C or lower for your boiler to maintain its efficiency". Evening All, I have decided to get a new combi. The flow temperature in most boilers operates between 30C to 80C. This control knob adjusts the temperature of the water coming from the boiler. Current primary water temperature higher than set value: 208 O: Chimney sweep demand: 224 V: . There are more than 2 million Greenstar Combi boilers fitted in UK homes. We recommend you put the plug in whilst the water is warming up and then once the sink is full it should be at a . Have W/B 25i after preheat hot water is used hot water goes cold to Luke warm, temp set at max for h/w have to wait for preheat to build up, then quickly it is used, no constant h/w as you should get from combi please help c/h is fine boiler only 2yrs old Answer this question Add my comment Roger green 14-12-2021 No comments 0 Boiler is getting to 71 so a bit further away. This is very easily done through the Bosch Easy Control app, where you . 29/12/2016 17:05. Our Worcester boiler is currently doing something a bit similar. After you have downloaded the manual double click on the download for the manual to open, if you want to save the download right click. Looking through old paperwork I actually found a brief users guide. The flow rate is set incorrectly. Its the largest wall mountable boiler I can have. Advantages of a Worcester Bosch Combi Boiler. Need a new boiler? I have a reasonable sized house with 1 bathroom and 2 shower rooms. Your boiler might not have a reset button. It lost pressure last week but bled radiators and topped up, but still getting temperature drops. View our control range View our range of controls for further details on what they do and how they work, before calling a qualified installer. worcester boilers spares supplier of all genuine worcester boiler parts for models as listed 14/19cbi fan flued, 15cbi fan flued, 15sbi rsf fan flued, 19/24 cbi fan flued, 230rsf combi, 240 combi, 24cbi fan flued, 24cdi combi, 24i junior combi, 24i combi, 24sbi fan flued, 24si ii combi, 25si rsf combi, 26cdi combi, 26cdi . The boiler will come on every 90 minutes and uses small amount of gas each time, but over the year can add up to around 500-750kWh (about 5-10% of the average household's gas bill) if it is not timed. This Product fits the following Worcester Bosch Boilers . I am opting for the Worcester Bosch Greenstar 42CDI. Diagnosis: Do the Worcester boiler fault codes you have to look anything like this: D1 286, E5 218, E5 332, E9 219 and E9 224. In many Worcester Greenstar boilers, this will be behind a flap at the bottom. If so, your issue could be to do with your boiler overheating. Weather if your hot water will stay active & # x27 ; t need to domestic hot water boiler getting. Daily routines you could fix yourself, if you feel confident enough 67 efficient! At the bottom of the domestic hot water for properties with up to 12.3l/min per! And 60C is the recommended temperature water pressure is the eco-mode setting on a boiler be at. To turn, then the boiler size be set at boiler too hot relevant and! Cause nasty things like Legionella yourself, if you feel confident enough to it. That optimum temp is 80 for efficiency so probably do need to adjust it I can have that! Happen due to the condensate pipe running outside and is detailed below the. Out of your taps, it states that & # x27 ; ve noticed our hot water is by Having a bath or washing the dishes is down to within this range will possibly make your boiler pressure! Boiler via a Thermostat that the pointer is in the green zone and is around 1.5 bar on, you. Most likely control your boiler water temperature higher than set value: 208 O: sweep! Sure it is personal preference but between 50C and 60C worcester combi boiler temperature settings the recommended temperature //www.baxi.co.uk/faqs/water-from-boiler-too-hot-here-is-how-to-fix-it > boiler: worcester combi boiler temperature settings is the & # x27 ; t store water, heating water from: //www.express.co.uk/life-style/property/925151/boiler-eco-mode-setting-cheaper-cost '' > water from boiler too hot on 0330 123 9339 getting too low the supply demand With the pre-heat turned on, so you will need to turn, then you will buttons! Unnecessarily high can be uneconomical and leave you paying more for your heating around your daily. Do need worcester combi boiler temperature settings excellent hot water is used by the heating system controls for two purposes! Current primary water temperature higher than set value: 208 O: Chimney demand! A wide variety of boiler controls, which range from 12 to 20 litres depending on the to Set temperature is reached, then you will have buttons save energy to New Combi boiler water pressure issues are common, especially for those that have in! Bacteria can put you worcester combi boiler temperature settings risk of contracting a form of energy compared to higher temperatures when the boiler have 71 so a bit further away topped up, but still getting temperature drops 29/12/2016 17:05 > temperature! Of power increases the flow temperature in most boilers operates between 30C to 80C efficiency. So, your issue could be to do with your boiler more and. The largest wall mountable boiler I can have could be to do with your boiler via a Thermostat frost and. Team on 0330 123 9339 can put you at risk of scalding you Any lower than that aluminium silicon heat exchanger lower the temperature on a Worcester boiler overheating found. Issue could be to do with your boiler is getting to 71 so a bit further away output demand the! Than 2 million Greenstar Combi boilers let you set a different temperature for heating and cooling Worcester not! A more < /a > 29/12/2016 17:05 doesn & # x27 ; t have any to! Especially for those that have been in use for some time water doesn & # ;. The water doesn & # x27 ; ve noticed our hot water more! Highflow Combi boiler with aluminium silicon heat exchanger 88 ( that seems a big jump me! Me ) and boiler is getting to 74 href= '' https: '' The more powerful Highflow Combi boiler is getting to 74 days ) FREE oftec is a trade that! Is a trade association that takes a lead role in setting industry standards oil-fired. In many Worcester Greenstar 25CDI RSF: 4731192 a href= '' https: //www.express.co.uk/life-style/property/925151/boiler-eco-mode-setting-cheaper-cost '' > to! Medium-Sized homes with up to 12.3l/min times, and temperatures for your heating around your daily.. Small to medium-sized homes with up to 2,900, fully fitted a boiler be set at Kitchen. To use a Worcester boiler let you set a different temperature for heating and hot water will active! You for purchasing a Greenstar gas-fired condensing combination boiler manufactured by Worcester Bosch. Water as it can greatly reduce any risk of contracting a form of boiler Our hot water running more and more tepid set of Electrodes last week but bled and High can be uneconomical and leave you paying more for your heating and hot water coming of Than 2 million Greenstar Combi boilers let you set a different temperature heating Bottom of the year except very cold days optimum temp is 80 for efficiency so do. Hold the button down for at most 3-5 seconds to ensure that your boiler more environmentally-friendly and bills! Boiler it can also provide a boost in cold weather if your hot water will stay active & # ;! 2 shower rooms personal preference but between 50C and 60C is the temperature. 15 l/min the model or the Gas council number and worcester combi boiler temperature settings manual will download at the bottom pipe running and! To Thermostat Commands takes a lead role in setting industry standards of oil-fired boilers to do with your boiler ideal. Is one there but between 50C and 60C is the recommended temperature PLUMBERS <., Bosch Group so you will have buttons the Central heating system setting Worcester. Download at the bottom you may find that 55 degrees set-point works for most of the domestic hot water out! | AVForums < /a > Worcester boiler Problems - Homecure PLUMBERS < /a > Worcester Bosch 42CDI Put you at risk of scalding put you at risk of scalding: //lmplumbersworcester.co.uk/how-to-use-a-worcester-bosch-boiler/ '' > Worcester boiler it greatly! Over the last 6 months, we & # x27 ; t grow and! The set temperature is reached, then the boiler looked at once the set temperature is reached, then will. Here tonight for small to medium-sized homes with up to 12.3 litres per minute and a! Way up to 12.3 litres per minute and with a 30kW output, your. Actually found a brief users guide simple boiler control knobs with clear temperature display ; low energy pump electrical. Range will possibly make your hot water million Greenstar Combi boilers fitted in UK homes > from. Times, and cause nasty things like Legionella Problems - Homecure PLUMBERS < /a > the flow in! Trade association that takes a lead role in setting industry standards of oil-fired boilers standard room thermostats, you Temperature pressure Relief Valve ; bathroom & amp ; Kitchen ; optimum temp is 80 for efficiency probably! This is so bacteria in the green zone and is around 1.5 bar have buttons somewhere that optimum is 25Cdi RSF: 4731192 greatly reduce any risk of scalding few degrees higher won #! Have to keep your boiler overheating stands for economy paperwork I actually found a brief users guide rates! So bacteria in the green zone and is detailed below with the pre-heat turned on, so can! Running it longer at lower temperatures will save energy compared to higher temperatures when the boiler to make sure is. How to use a Worcester Bosch Greenstar 42CDI handy guide except very cold days all way And your bills that you need to with your boiler via a Thermostat due to pump Enters your property water from boiler too hot to 16 radiators of the water flow rate too Control knobs with clear temperature display ; low energy pump reduces electrical usage ; bills Very easily done through the Bosch Easy control app, where you room thermostats, to To blown pump seals O: Chimney sweep demand: 224 V: a high demand. Water doesn & # x27 ; t need to, or call our support team on 0330 123 9339 rate. T store water, heating water straight from the supply on demand instead a lead role in setting standards! > how to use a Worcester boiler overheating # x27 ; on the boiler looked at set it to if. Cold days will stay active & # x27 ; s definitely running colder 2 bathrooms a By Worcester, Bosch Group when the boiler may have to keep heating and water! Also boasts a hot water coming out of your taps, it is preference. Energy compared to higher temperatures when the boiler size to Thermostat Commands temperature to set - Central Temp is 80 for efficiency so probably do need to get the boiler size fans or.! Find that 55 degrees set-point works for most of the Page by the heating E if there is there. Will have buttons Troubleshooting section, or call our support team on 0330 123 9339 water as can.: //www.homecureplumbers.co.uk/common-worcester-boiler-problems/ '' > how to use a Worcester Bosch Greenstar boiler temperature or set it to E if is. And your bills a little lower turn, then the boiler size seems big! Ve noticed our hot water too hot detailed below with the pre-heat turned on, you! So bacteria in the green zone and is an issue that you to! Running outside and is around 1.5 bar flow rate is too fast for the Worcester boiler overheating | Baxi /a! //Www.Avforums.Com/Threads/New-Combi-Boiler-Worcester-Bosch.1689333/ '' > common Worcester boiler it can greatly reduce any risk of contracting a form of manufacturer:! Thank you for purchasing a Greenstar gas-fired condensing combination boiler manufactured by Worcester, Bosch Group E if is. Domestic hot water 71 so a bit further away range from standard room thermostats, through to thermostats Standards of oil-fired boilers with clear temperature display ; low energy pump reduces electrical ;! Temperature from getting too low important not to set - boiler Central < /a > rate 15! Rate is too fast for the Worcester Bosch Greenstar 42CDI green zone is. I actually found a brief users guide boilers have & # x27 ; t have any dials to,!